Key Compliances under Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations, 2023 (Part – II)

Background:
Central Electricity Authority (CEA) Regulations, 2023, were formulated under the Electricity Act, 2003 to enhance electrical safety and ensure proper operation of electrical installations across India. These regulations address both high- and low-voltage installations, specifying standards for design, installation, operation, maintenance, testing, and protection measures. They aim to prevent electrical accidents, reduce risk of fire and shock hazards, and ensure reliability in power supply systems. Key elements include mandatory earthing, use of residual current devices, periodic inspections, training of personnel, transformer and high-voltage installation safety, and automatic protection mechanisms in abnormal conditions.

Applicability:

These regulations apply to:

  • Every generating station owner must ensure training of operation and maintenance personnel through its own institute or one recognized by the Authority or State Government, as per prescribed guidelines.
  • Suppliers of electricity to consumers and public utilities, ensuring compliance with safety standards.
  • Periodic inspections, testing, and certification apply to owners, suppliers, and consumers as per the relevant voltage and type of installation.

Compliance Requirement Under the Regulations

  1. Minimum Size and Strength of Trolley Wires (Regulation 91)

No trolley wire shall have a cross-sectional area less than 0.5 sq. cm or an actual breaking load of less than 2,000 kg.

  1. Minimum Height of Trolley Wires above Ground in Traction Feeder (Regulation 92)

A trolley wire or traction feeder on the same supports as a trolley wire shall at no place be at a height from the surface of the street of less than 5.2 metres, except where it passes under a bridge, fixed structure, tunnel, or mine shaft, in which case it shall be suspended to the satisfaction of an Electrical Inspector.

  1. Earthing of Guard Wires (Regulation 93)

Every guard wire shall be connected with earth at each point at which its electrical continuity is broken and shall also be connected with the rails at intervals of not more than five spans.

  1. Obtain Approval Before Carrying Out Traction Work Near Magnetic Observatories (Regulation 94)

Traction works shall not be carried out in the vicinity of geomagnetic observatories and laboratories without the concurrence of the Central Government or authorised officer.

  1. Maintain Detailed Operational, Testing, and Incident Daily Records for Traction Systems (Regulation 95)

The owner shall keep daily records of: (i) maximum working current at source; (ii) maximum working voltage at source; (iii) potential difference as per Regulation 86; and (iv) leakage current, if any, as per Regulations 87 and 88. Occasional records of every test made, every stoppage of leakage with time occupied, and particulars of any abnormal occurrence shall also be maintained.

  1. Ensure Compliance with Electrical Safety Requirements in Mines and Oil-Fields (Regulation 97(1))

Responsible persons in mines and oil-fields must ensure compliance with electrical safety regulations and enforce adherence by employees. In the case of power stations, transformer substations, and related installations supplying electricity solely for the working of mines and not within the precincts of a mine, an Engineer holding a degree in Electrical Engineering with adequate experience may be appointed as manager.

  1. Annual Returns for Mines under Schedule IX and X (Regulation 98(1))

On or before 1st February each year, for every mine or oil-field, persons specified in Regulation 97 shall submit to the Electrical Inspector of Mines returns in Schedule IX and Schedule X forms, detailing the size and type of apparatus and particulars of its use.

  1. Notice for Bringing New Installation in Mine/Oil-Field with Apparatus Details and Location (Regulation 98(2))

Persons specified in Regulation 97 shall give the Electrical Inspector of Mines at least 7 days’ prior written notice before using any new installation in a mine or oil-field, with details of apparatus and location, except for telecommunication or signalling apparatus. For additions or alterations to existing installations ≤650V, immediate written notice shall be given to the Electrical Inspector of Mines before use. In emergencies risking life, machinery, or mine safety, intimation shall be given within 24 hours with a status report and self-certification of the additions or alterations undertaken.

  1. Maintain Updated Electrical Plans and Diagrams in Mines and Oil-Fields (Regulation 99(1) to (4))

A plan (at the same scale as the Mines Act plan) and Single Line Diagram shall be kept at the mine office from the commencement of supply, showing all fixed apparatus and conductors. Plans shall be examined and corrected as often as necessary to remain up-to-date, with dates of examination entered by the manager or owner, and shall be available to the Inspector or Inspector of Mines at any time.

  1. Ensure Lighting, Communication, and Fire Safety in Mines and Oil-Fields (Regulation 100(1) to (4))

Adequate electric illumination as per relevant standards shall be provided in mines. Efficient means of communication shall be provided between switchgear locations and shaft bottoms. Fire extinguishing appliances of adequate capacity shall be installed and properly maintained in every place containing apparatus. For mines where dumpers or trackless vehicles are operated, the minimum clearance above ground of the lowest conductor of overhead lines shall not be less than twelve metres at road crossings.

  1. Ensure Safe Installation and Isolation of Transformers and Switchgear (Regulation 101(1) to (3))

Transformers and switchgear shall be in a separate room, compartment, or box, or protected from damage and fire spread. If fire risk exists, no inflammable material shall be used in construction or fittings; such spaces shall be substantially built, kept dry, illuminated, and efficiently ventilated. All apparatus that has to be worked or attended to shall be placed at a spacious working place accessible, clear of obstruction, and free from danger.

  1. Ensure Proper Earthing of Electrical Installations in Mines (Regulation 102(1) to (5))

Where earthing is required in a mine, it shall be connected to the surface substation earthing. Metallic sheaths, coverings, handles, joint boxes, switchgear frames, instrument covers, switch or fuse covers, lamp holders, frames, and bedplates of generators, transformers, and motors (including portable) shall be earthed. All conductors of an earthing system shall have conductivity at least equal to fifty percent of that of the largest conductor used solely to supply the apparatus being earthed.

  1. Provide Protective Equipment and Earth Fault Protection Systems in Mines (Regulation 103(1) to (3))

Entities must ensure earth fault limits are maintained, protective relay settings are appropriate, operations of switchgear and relays are recorded daily, and the effectiveness of the protective system is checked by calibrating and testing at least once a year, with results recorded. Numerical relays shall be tested as per OEM guidelines or relevant standards at least annually.

  1. Ensure Prescribed Voltage Limits for Electrical Systems in Mines and Oil-Fields (Regulation 104)

For belowground mines, transmission voltage shall not exceed 11 kV and use voltage shall not exceed 6.6 kV. Hand-held portable apparatus shall not exceed 125V. For portable hand-lamps in belowground mines and hazardous areas of oil fields, voltage shall not exceed 30V. For remote control or electric interlocking circuits, voltage shall not exceed 30V for belowground mines or hazardous areas of oil fields.

  1. Ensure Transformer Protection Against Overvoltage Risks in Mines (Regulation 105)

In mines or oil-fields, transformers used for providing voltages to control circuits, remote control, interlocking, or hand-held apparatus shall have suitable provision to guard against danger by reason of the lower voltage apparatus becoming accidentally charged above its normal voltage by leakage from or contact with the higher voltage apparatus.

  1. Ensure Safe Construction and Protection of Switchgear and Electrical Connections (Regulation 106)

Switchgear and electrical connections shall be enclosed, mechanically strong, properly insulated, and protected against contact, fire, explosion, and faults. All live parts shall be protected or enclosed to prevent accidental contact and to prevent danger from arcs, short-circuits, fire, water, gas, or oil. Where there is risk of igniting gas, coal dust, oil, or other inflammable material, all parts shall be so protected as to prevent open sparking.

  1. Ensure Safe Disconnection and Protection of Electrical Supply Systems in Mines (Regulation 107)

Properly constructed switchgear with protective mechanisms shall be provided to safely disconnect supply from systems, motors, and feeders, with operator availability ensured and automatic disconnection during faults, including interlocking with ventilators and fans. Every motor shall be controlled by switchgear capable of disconnecting supply to the motor and connected apparatus. Suitable switchgear shall automatically disconnect supply under over-current, earth fault or leakage, under-voltage, and single phasing conditions.

  1. Ensure General Safety, Maintenance, and Safe Operation of Electrical Apparatus (Regulation 111)

All electrical apparatus shall be maintained free from dust, moisture, and obstruction; storage of inflammable material nearby shall be prevented; faulty circuits shall be isolated; only authorised persons shall operate apparatus; safety notices in Hindi and local language shall be displayed; and interlocks shall be provided to prevent handling of live connections. Supply shall be disconnected while changing lamps. All apparatus shall be operated only by designated persons.

  1. Ensure Electrical Safety Measures During Shot-Firing Operations in Mines (Regulation 113)

When shot-firing is in progress, adequate precautions shall be taken to protect electrical apparatus and conductors from injury. Current from lighting or power circuits shall not be used for firing shots. Shot-firing cables shall conform to relevant standards and shall not come into contact with other cables or electrical apparatus.

  1. Implement Safety Precautions for Electrical Signalling Systems in Mines/Oil-Fields (Regulation 114)

Where electrical signalling is used, adequate precautions shall be taken to prevent signal and telephone wires from coming into contact with other cables and apparatus. The voltage in any one circuit shall not exceed 30V. Contact-makers shall be so constructed as to prevent accidental closing of the circuit. Bare conductors, where used, shall be installed on suitable insulators.

  1. Obtain Approval for Using Haulage by Electric or Battery Locomotives in Mines (Regulation 115)

Haulage by electric locomotives on the overhead trolley-wire system at voltage not exceeding 650V and haulage by storage battery locomotives may be used in mines only with the prior permission in writing of the Electrical Inspector of Mines and subject to such conditions as may be imposed in the interest of safety.

  1. Ensure Earthing of Neutral/Mid-Point of AC Systems above 30V in Mines or Provide Ground Protection (Regulation 116)

For all AC systems above 30V in mines or oil-fields, the neutral or mid-point shall be earthed as per Regulation 102. Blasting and signalling systems are exempt. In the case of unearthed neutral systems, suitable ground protection approved by the Electrical Inspector of Mines shall be provided to isolate faulty sections.

  1. Appoint Qualified Electrical Supervisors and Electricians for Mining Installations (Regulation 117(1), (2), (3) & (4))

The owner, agent, or manager of a mine or oil-field wells shall appoint electrical supervisors in writing as per DGMS guidelines and inform the Authority or as directed by the Electrical Inspector of Mines. The supervisor shall hold a valid Electrical Supervisor’s Certificate of Competency for mining installations. Adequate electricians as per DGMS guidelines shall also be appointed in writing; electricians shall hold a licence under Regulation 31(1).

  1. Appoint Substitute Supervisors and Maintain Log-Book as per Schedule XI (Regulation 117(8) & (9))

Whenever an electrical supervisor is absent, a substitute shall be appointed in writing before the absence commences. The supervisor or substitute must maintain a log-book in the Schedule XI format, including daily logs and test records, at all times.

  1. Arrange Training for Mine Electrical Personnel as per DGMS Guidelines (Regulation 118(1), (2))

Persons engaged in the operation and maintenance of electrical installations in mines shall undergo training specific to Coal, Oil, or Metal mining installations as per DGMS-prescribed syllabus, with intimation in writing to the Authority. The owner, manager, or agent shall arrange training through their own institute or any institute recognised by the Central or State Government.

  1. Refresher Training for Persons Maintaining/Operating Electrical Installations in Mines (Regulation 118(3))

Refresher training shall be given at intervals not exceeding two years. The owner, manager, or agent shall maintain a register or electronic record of trained persons, due dates, and related details, and produce it before the Electrical Inspector of Mines when required.

  1. Additional Safety Requirements for Renewable Generating Stations (Regulation 119)

The regulations under Chapter X of the CEA Safety Regulations, 2023 shall be applicable to renewable generating stations in addition to the regulations provided from Chapters I to VII.

  1. Safety Requirements for Biomass/Waste to Energy Installations (Regulation 120)

All biomass plants and waste-to-energy plants — including Municipal Solid Waste or Refuse Derived Fuel plants — shall comply with the safety standards mentioned in Regulations notified by the Authority under clause (e) of sub-section (2) of Section 177 of the Electricity Act, 2003.

  1. Safety Requirements for Solar Installations (Regulation 121(1))

Solar installations shall: provide clear pathways of at least 75 cm wide with handrails for roof access and emergency exit in rooftop systems; maintain clear walkways between panel rows and columns for cleaning and maintenance; lay cables in trenches for ground-based PV installations; and protect ground-mounted installations with fencing of at least 1.8 m height. Disconnection switches or circuit breakers in combiner boxes shall be at readily accessible locations. Inverter units shall be installed at the building periphery near panels with DC cables UV-protected or routed through UV-protected pipes.

  1. Earthing Requirements for Solar Installations (Regulation 121(2))

Solar installations shall comply with relevant earthing standards. Inverter cabinet frames shall be connected to the earthing bus bar through earthing terminals using flexible braided copper wire. All metal casing, shielding, array structures, equipment, inverters, and control systems shall be earthed through proper earthing. The earthing system shall connect all non-current carrying metal receptacles and structures in one long run with earth strips interconnected by proper welding and not bolted.

  1. Protection/Testing/Interlocking Requirements for Solar Installations (Regulation 121(3))

Solar installations shall have lightning and overvoltage protection with required lightning arresters. Every combiner box shall be equipped with suitable surge protective devices having arc extinguishing capability to prevent fire risk. Input circuits of combiner boxes shall have over-current protection; output circuits shall have isolation protection; earth fault protection and insulation monitoring for photovoltaic arrays and inverters shall be provided.

  1. Requirement to Prevent Fire for Solar Installations (Regulation 121(4))

A fire detection system and automatic fire suppression system shall be provided for solar installations and shall comply with the relevant standards.

  1. Safety Requirements for Floating Solar Photovoltaic Energy Installations (Regulation 121(5))

PV modules and associated structures of floating solar power plants shall comply with relevant standards for tests such as salt mist, ammonia corrosion, environmental stress cracking of High Density Poly Ethylene (HDPE), stress cracking resistance of HDPE, and standard test method for tensile properties of plastics.

  1. Safety Requirements for Wind Energy Installations (Regulation 122)

All wind energy generation systems — including wind turbines, wind power plants onshore and offshore connected with the grid — shall comply with relevant standards. Transformers for wind turbine applications shall be as per the relevant standards. Portable fire extinguishers shall be kept at various locations in plants for immediate action in case of fire. Any wind turbine worker exposed to a potential fall shall be supported by a certified fall arrest system such as a full body safety harness.

  1. General Safety Requirements for EV Charging Stations (Regulation 124)

EV charging stations shall have separate overload protection for input and output as per standards. Socket outlets shall be at least 800 mm above finished ground level. No cord extension set or second supply lead shall be used for connecting an EV to the charging point. No adaptor shall be used to connect a vehicle connector to a vehicle inlet; charging distance shall not exceed 5 m. After disconnection, voltage shall be ≤42.4V peak (30 Vrms) or 60V DC and energy <20 J. Lightning protection shall be provided as per standards.

  1. Provide Earthing and Electrical Protection Systems for EV Charging Stations (Regulation 125)

Each EV charging point shall have a dedicated protected sub-circuit, coordinated protection devices, earth continuity monitoring, and proper earthing conductors. An earth continuity monitoring system that disconnects supply in the event of ineffective earthing to the vehicle shall be provided. The charging lead shall be fitted with an earth-connected metal shielding; a protective earth conductor shall establish an equipotential connection between the supply earth terminal and the conductive parts of the vehicle.

  1. Ensure Fire Prevention Systems for EV Charging Stations (Regulation 126)

The enclosure of electric vehicle supply equipment shall be made of fire retardant material with self-extinguishing property and free from halogen. A fire detection, alarm, and control system shall be provided as per relevant standards.

  1. Conduct Testing of EV Charging Stations as per Standards (Regulation 127)

The owner of the charging station shall ensure that tests as specified in the manufacturer’s instructions for residual current devices and the charging station have been carried out. Records of such testing shall be maintained.

  1. Maintain and Retain Records for EV Charging Stations (Regulation 128)

The owner of the charging station shall keep records of design, construction, and labelling to ensure compatibility with a 50 Hz standard voltage supply. Records of relevant test certificates, results of every inspection, testing, and periodic assessment, and details of any issues observed shall be maintained. All records shall be retained in hard or electronic form for at least seven years and shall be provided to officials during inspection.

  1. General Safety Requirements for HVDC Stations (Regulation 130)

A wire mesh shall be provided beneath the walkway wherever constructed above the hanging valves in the valve hall. Cables used for sensitive measurements shall be laid in separate and completely screened or covered channels or galvanised steel pipes. A separate emergency source of illumination with automatic initiation shall be provided in every room or compartment of the HVDC station. No oil-immersed apparatus shall be kept within the valve hall. All doors of compartments containing modules with laser diodes and fibre optic cable junction boxes shall be locked and marked with laser warning symbols.

  1. Fencing of Filter Banks at HVDC Stations (Regulation 131)

AC and DC filter bank areas shall be efficiently protected by fencing or other means not less than 1.8 m in height to prevent access by unauthorised persons, and the fencing shall be effectively earthed. The gate of the fencing and the earth switch of the filter bank shall be interlocked such that the gate can be opened only after complete disconnection and discharging of the filter bank.

  1. Earthing Requirements for HVDC (Regulation 132)

The converter transformer shall have a separate perimeter earthing conductor. The line-side neutral of the transformer bank shall be earthed at one point only. The air-cored reactor support structure circumference shall be earthed without forming closed loops. The Radio Frequency Interference screen of the valve hall and all metallic sheet, prefabricated structure members, and trusses housing HVDC apparatus shall be electrically connected and effectively earthed.

  1. General Safety Requirements for Gas Insulated Substations (GIS) (Regulation 134)

A separate emergency source of illumination with automatic initiation shall be provided in every room or compartment of the GIS. A cable cover protection unit shall be provided between flanges of the GIS and the cable termination unit. GIS installations of 220 kV and above shall be provided with a partial discharge monitoring system. SF6 gas leakage rate from any single compartment shall not exceed the limits stipulated in the relevant standards.

  1. Earthing Requirements for Gas Insulated Substations (Regulation 135)

The enclosure of each GIS bay shall be earthed for high frequency transient voltage as per OEM recommendations, in addition to the regular earthing. Travelling wave energy generated inside the GIS due to switching operations shall be diverted to earth by providing effective earthing from bushing shroud to earth. Earthing of GIS installations shall be as per relevant standards.

  1. Reporting of Reasons of Failures of 220 kV and Above Electrical Installations and Corrective Measures (Regulation 48(8))

Owners of electrical installations must report failures of 220 kV and above transformers, reactors, or transmission towers to the Authority within 48 hours. The causes of failure and preventive measures must be submitted within one month using the forms provided in Schedule VII.

  1. Testing, Operation, and Maintenance of Electric Installations Exceeding 650V (Regulation 48(1)–(7))

Before approval is accorded by the Electrical Inspector under Regulation 45, manufacturer’s type, acceptance, and routine test certificates shall, if required, be produced for all tests as per relevant standards. No new apparatus, cables, or supply lines above 650V shall be commissioned without site testing. Equipment disconnected for six months or more shall be reconnected only after such testing. All equipment shall be maintained in good condition with periodic testing; records of tests, trippings, maintenance, and repairs shall be properly maintained.

  1. Making of Cables (Except Flexible Cables) for Mining Applications (Regulation 108)

Cables (except flexible) shall be insulated and protected from mechanical damage and supported at intervals to prevent damage. Only concentric, single, two-core, or multi-core cables with metallic covering containing conductors shall be used for supply above 125V or where the Electrical Inspector sees risk of igniting gas or dust. Metallic covering shall be continuous, effectively earthed, and corrosion-protected with conductivity at least 50% of the largest conductor.

  1. Making of Flexible Cables for Portable or Transportable Apparatus in Mines (Regulation 109)

Flexible cables for portable or transportable apparatus shall be two-core or multi-core (except for welding), properly insulated and protected. Metallic covering shall not alone serve as an earth connection. Proper connectors shall be used (bolted for above 650V–11 kV, with cable anchored); a circuit breaker shall be provided at joints with main cables. Length shall not exceed 100 m (exceptions up to 1,000 m). Cables shall be supported, used only for portable or transportable apparatus, and isolated when not in use.

  1. Compliances for Using Portable and Transportable Machines in Mines (Regulation 110)

The operator of an electrically driven coal-cutter or portable or transportable machine shall not leave it while operating. Before leaving the area, the operator shall ensure supply is disconnected from the flexible cable. During operation, the operator shall ensure the flexible cable is not dragged by the machine. All portable and transportable machines in underground mines shall operate on remote control from the concerned switchgear with pilot core protection.

Penalty & Consequences

Section 146 of the Electricity Act, 2003 — General Penalty for Non-Compliance

Whoever fails to comply with any order or direction issued under the Electricity Act, 2003, or contravenes — or attempts or abets the contravention of — any provision of the Act or any rules or regulations made thereunder, shall be punishable with imprisonment for a term which may extend to three months, or with a fine which may extend to one lakh rupees, or with both, in respect of each offence. In the case of a continuing failure, a further fine which may extend to five thousand rupees for every day during which the failure continues after conviction of the first such offence shall also be imposed. This provision applies uniformly across all compliance obligations under the CEA (Measures relating to Safety and Electric Supply) Regulations, 2023.

Disclaimer: The information contained in this Article is intended solely for personal non-commercial use of the user who accepts full responsibility of its use. The information in the article is general in nature and should not be considered to be legal, tax, accounting, consulting or any other professional advice. We make no representation or warranty of any kind, express or implied regarding the accuracy, adequacy, reliability or completeness of any information on our page/article. 